Pages

Sunday, March 18, 2012

FRM-40735:ON-ERROR trigger raised unhandled exception ORA-06508

After converting older version of oracle forms to forms 10g using forms Migration Assistant, you are not be able to open the application or log in to the application via web. When access from developer suit 10g, it will run without any problems. One of the problem could be the related ORACLE LIBRARY PATH which attached to it. Some times this can happens when you are changing the library path according to the module or work area you work at that moment.


In older versions of forms the library path is mapped to the client pc and the forms application refer to the mapped drive letter. In the web we couldn't find specific path. It is relative. It will automatically refer the path.


If you have above mentioned problem, you will get message from oracle form builder. It says cannot attache specific libraries to your form source. Sometimes you wont get this message but wont be able to open the form. when you look in to the form source in form builder, you will see that form didn't include any library. 


There's few solution available for this matter. 

  • Open the form in Oracle form builder. Click on Attached library and plus sign item on Object Navigator.  Locate the need .plls and press YES on the message which ask whether to remove path or not.
  • Go to the regedit through Command Prompt. Go to forms_path if you are  working with 10g2 , otherwise go to forms90_path and enter the related library path to that.
  • Go to the Oracle folder where installed it in your computer and go to the forms folder if you are using oracle 10g2. Otherwise go to forms90 folder. In that folder, go in to the server folder and you can find ENV file named Default. open it on notepad or wordpad. It includes something like "FORMS_PATH" if you are using 10g2. Otherwise "FORMS90_PATH" give the related library to that path and save it. Now whole forms is under your control. 
Now you can open the form and access via web successfully. 


Additional....

  • Don't use long paths for Library folder.
  • Keep the latest libraries which are in SVN.
  • Always replace the regedit path and default.env path when you are changing the module or oracle version accordingly.
  • Oracle 10g1 use FORMS90 AND Oracle 10g2 use FORMS.

1 comment:

  1. Compare all .pll files in $AU_TOP/resource/ from other running instance and copy paste the missing
    (JE.pll/VERT.pll/IGILUTIL.pll/ or any other .pll) files in $AU_TOP/resource/ then bounce the services.